Research Updates

Recent highlights, upcoming deliverables, and the latest developments

Recent Highlights

FLISR Performance Testing and Training
Test cases for FLISR systems across range of scenarios as well as improvements to design/implementation.
DCC Capabilities to Support DER Services
Outlined core capabilities and steps to consider
DSO Operator Certification
Proficiencies necessary to become a Certified DSO and proposed methods to manage this certification process.
Short-Term PV Forecasting
Outlined data requirements and opportunities to leverage with FLISR.

For the full list of past research, click here

2025 Meeting Calendar

Task force meetings are open to funders of the distribution operations research. Reach out to Lindsey Rogers if you are interested in learning how to participate.

Date Event Link
01/28/2025 Program 200 Webcast: 2025 Member Orientation / Pre-Advisory Discussion

Meeting Info

02/11/2025 Operations Research (P200C) 2025 Taskforce Kick-Off

Meeting Info

04/24/2025 Overview and Discussion on the Development of AI Use Cases for Distribution Operations

05/21/2025 Distribution Operations with DER - Joint w/ 174

June 2025 ARCHER Data Exchange Platform Report Out

07/08/2025 Operations Research Mid-year Update

August 2025 Operations Topical Task Force Meeting - Topic TBD

September 2025 Operations Topical Task Force Meeting - Topic TBD

October 2025 Operations Topical Task Force Meeting - Topic TBD

November 2025 Operations Topical Task Force Meeting - Topic TBD

12/09/2025 Operations Research End of Year Webcast

2025 Planned Deliverables

Title Description
Distribution Operations Guidebook Expansion and revision of guidebook with foundational knowledge relevant to today’s DCCs supporting implementation of DA and DMS applications.
Model Readiness for Grid Operations: DMS Model Validation and Verification for Power Flow Develop and implement methods to validate operational grid models. Demonstrate these methods using test models and synthetic data to ensure that utilities can assess and improve their model quality.
Automated DA Benefits Reporting: Requirements Document Define OMS & DMS reporting requirements to enable automated DA benefits calculation.
Reliability Planning Methods and Application Guide Translate recent developments in predictive reliability modeling to actionable recommendations, guidance, and practices.
Advanced VVO Performance Testing and Tutorial Provide insight into validating the effectiveness of VVO systems through virtualized field testing. By developing a test framework, utilities can use it to evaluate their DMS or provide operator training in conjunction with EPRI's OPS Lab.
DMS Experience Webcast Series Share lessons learned, leading practices, and success strategies to move the industry forward in deployment of high value ADMS applications.
Distribution Operations with DER Reference Guide Provide a cohesive, central reference guide of DER impacts and opportunities for distribution operations.
RESILIENCE: Adding Operators to Mutual Assistance Teams Explore recent experiences with utilities beginning to send operators on mutual assistance teams, to identify early successes, gaps, lessons learned, and the need for new research.
AI Use Cases for Distribution Operations + Demo within DOIG Develop top AI use cases for the distribution control center in Year 1 and select one (3-part Comms) for demonstration using recordings supplied by DOIG members.
On demand training / operating instructions Adapt a mobile application developed to support field crew and DCC operator interactions.